33 HVAC ERROR CODES

HVAC Error Codes DirectoryMetro Vancouver

Comprehensive error code reference for furnaces, boilers, heat pumps, and ACs across all major brands

CALL NOW: 778-909-5731
E201CRITICAL

Ignition Lockout (Furnace)

Furnace has attempted ignition 3 times and failed, triggering a safety lockout with no heat.

LennoxCarrierTrane+4
E205HIGH

Pressure Switch Stuck Open (Furnace)

Furnace pressure switch detects inadequate draft and prevents firing for safe exhaust venting.

LennoxCarrierTrane+4
E215HIGH

Flame Sensor Failure (Furnace)

Flame sensor not detecting flame after gas valve opens, shutting down the burner.

LennoxCarrierTrane+4
U2HIGH

Serial Communication Error (Heat Pump)

Mitsubishi heat pump communication lost between indoor and outdoor units.

MitsubishiDaikinFujitsu+2
E001CRITICAL

Air Supply/Exhaust Blockage (Boiler)

Navien boiler detected blockage in air supply or exhaust venting and shut down.

NavienViessmannWeil-McLain+2
E003CRITICAL

Ignition Failure (Boiler)

Boiler failed to ignite burner after multiple attempts and locked out.

NavienViessmannWeil-McLain+2
E016CRITICAL

Overheating (Boiler)

Boiler water temperature exceeded maximum safety limit, triggering emergency shutdown.

NavienViessmannWeil-McLain+2
A1HIGH

PCB Fault (Heat Pump)

Daikin heat pump printed circuit board has detected an internal fault.

DaikinMitsubishiFujitsu+2
A5MEDIUM

Freeze Prevention Active (Heat Pump)

Heat pump freeze prevention mode activated, temporarily stopping operation.

DaikinMitsubishiFujitsu+4
E110HIGH

Flow Sensor Issue (Boiler)

Boiler flow sensor not detecting sufficient water flow for safe operation.

NavienViessmannWeil-McLain+2
13HIGH

Limit Circuit Lockout (Furnace - Lennox)

Lennox furnace limit switch opened 5 times in one call for heat, locking out system.

Lennox
14CRITICAL

Ignition Failure (Furnace - Lennox)

Lennox furnace failed to ignite after multiple attempts.

Lennox
52CRITICAL

No Flame - Burner Shutdown (Boiler - Viessmann)

Viessmann boiler detected flame failure during operation and shut down burner.

Viessmann
2FMEDIUM

Outdoor Temperature Sensor Fault (Boiler - Viessmann)

Viessmann boiler outdoor temperature sensor has failed or reading incorrectly.

Viessmann
001CRITICAL

Blocked Vent (Boiler - Weil-McLain)

Weil-McLain boiler vent blockage detected, system shut down for safety.

Weil-McLain
89CRITICAL

Inverter Module Error (Heat Pump - Trane)

Trane heat pump inverter drive module fault detected.

TraneCarrierLG+1
E3CRITICAL

High Pressure Switch Trip

High pressure switch opened due to excessive refrigerant pressure.

CarrierTraneDaikin+2
E4HIGH

Low Pressure Switch Trip

Low pressure switch opened due to suction pressure dropping too low.

CarrierTraneDaikin+3
E225MEDIUM

Line Voltage Error (Furnace)

Furnace control board detected incorrect line voltage.

LennoxCarrierTrane+4
E007HIGH

Water Pressure Sensor Error (Boiler)

Boiler water pressure sensor reading outside normal operating range.

NavienViessmannWeil-McLain+2
E012HIGH

Combustion Fan Error (Boiler)

Boiler combustion fan not operating at correct speed or has failed.

NavienViessmannLochinvar
E215HIGH

Compressor Sensor Error (Heat Pump)

Heat pump compressor temperature or pressure sensor has failed.

DaikinMitsubishiFujitsu+4
9-FLASHCRITICAL

Rollout Switch Tripped (Furnace)

Rollout switch detected flames escaping burner compartment, furnace shut down.

LennoxCarrierTrane+4
CH05HIGH

Outdoor Unit PCB Error (Heat Pump - LG)

LG heat pump outdoor unit control PCB has detected a fault.

LG
E255MEDIUM

PCB Communication Error (Boiler - Navien)

Navien boiler control board communication error between main and display PCBs.

Navien
E0MEDIUM

EEPROM Error (Heat Pump - Carrier)

Carrier heat pump outdoor control board EEPROM data corrupted.

Carrier
6-FLASHHIGH

Blower Motor Fault (Furnace)

Furnace control board detected blower motor circuit fault.

LennoxCarrierTrane+4
E235HIGH

Low Gas Pressure (Furnace/Boiler)

Gas supply pressure too low for proper equipment operation.

LennoxCarrierTrane+4
E227MEDIUM

Flame Amplifier Fault (Furnace)

Flame sense circuit not generating enough microamp signal.

LennoxCarrierTrane+4
A2HIGH

Flue Gas Temperature Too High (Boiler)

Boiler flue gas temperature exceeded maximum safe limit.

ViessmannNavienWeil-McLain+2
65HIGH

Indoor Fan Motor Fault (Heat Pump - Samsung)

Samsung heat pump indoor fan motor not operating correctly.

SamsungLGFujitsu
8-FLASHHIGH

Draft Inducer Motor Fault (Furnace)

Furnace draft inducer motor not running or not reaching proper speed.

LennoxCarrierTrane+4
E001HIGH

Refrigerant Leak Detection (Heat Pump)

Heat pump refrigerant leak detection sensor has activated.

FujitsuDaikinMitsubishi+1

Don't See Your Error Code?

We diagnose all HVAC error codes 24/7